<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-09 15-14-55
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
14 kHz 71 kHz 18338 10,0665
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 4,79 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 71 kHz MIN: 14 kHz % above 76 kHz: 10,0665 Acquired: 2025/07/09 15.13.51 Total samples: 18338 Equivalent time: 0:15:16 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,2 dBr MIN: 2,3 dBr AVE: 4,79 dBr % above 12,2 dBr: 0,0 Last value: 5,4 dBr (2025/07/09 15.13.51) 15.00 15.02 15.04 15.06 15.08 15.10 15.12 0 2 4 6 Pm [dBr]